The HL-800K infrared laser thermometer is very robust and is well suited to applications where contact measurement is not possible or desirable. A Type K Thermocouple can be connected via a miniature plug.
The HL-800K is very easy to use: simply point and measure. The measurement is read within 1 second and the laser pointer helps to precisely identify your measurement point. The unit has an adjustable emissivity and a 13:1 spot to distance ratio.
As standard the thermometer has a High / Low alarm facility, as well as Min, Max, Average and Difference functions, together with a data logging function (20 memory readings). The temperature readouts are backlit making them easy to read, even in the dark. A wide range of hand-held thermocouples are also available.
Supplied with a 9V battery and soft case.
Note: this product is not suitable for measuring human temperatures. The HL-BODY Infrared Body Thermometer is a suitable alternative.Features Laser targetting
Adjustable emissivity from 0.10 to 1.0
°C/°F selectable
Accepts Type K Thermocouple (mini plug)
Data logging function (20 memory readings)
Automatic data hold
Auto power off / low battery indication
Backlit LCD display
Min/Max, Average, Difference displays
High and Low alarm
Over range indication
Supplied with 9V battery and soft case
180mm x 106mm x 48mm
Technical Details |
---|
Range | Infrared | -50°C to +800°C (-58°F to +1472°F) |
Type K | -50°C to +1370°C (-58°F to +2498°F) |
Resolution | 0.1°C |
Accuracy | Infrared | ±1.5% of reading ±2°C -20°C to +200°C |
±2.0% of reading ±2°C +200°C to +538°C |
±3.5% of reading ±5°C +538°C to +800°C |
±5°C -50°C to +20°C |
Type K | ±1.5% of reading ±3°C -50°C to +1000°C |
±2.0% of reading ±3°C +1000°C to +1370°C |
Optical Resolution | 13:1 (distance to spot size ratio) |
Emissivity | Adjustable from 0.10 to 1.0 |
Response Time | < 1 second |
Power | 1 x 9V battery (supplied) |
Dimensions | 180mm x 106mm x 48mm |
Weight | 250g |
Note: supplied product colour may vary. Type K sensor not included.